The 2018 edition on the code also added a fourth option specifically for the testing of your epss equipment for your emergency lighting system as opposed to the lighting system itself.
Emergency light testing requirements uk.
Additional information on servicing can be found in bs 5266 1.
Aside from installing emergency lights employers also have the legal responsibility to do emergency light testing in their business premises this is to ensure that the system is in good condition and will automatically and properly work during emergency situations.
Annual emergency lighting testing.
General information about emergency lighting testing.
And the emergency lighting system must be arranged to provide illumination automatically in the event of any interruption of normal lighting section 7 9 2 3.
In bs 5266 1 1999 the legislation clearly states the requirements of testing emergency lighting units.
Bs en 50172 bs 5266 8 emergency escape lighting systems specify the minimum provision and testing of emergency lighting for different premises.
The role of the responsible person in a premises is to carry out periodic checks.
Section 7 9 3 of the life safety code addresses the nfpa s requirements for periodic testing of emergency lights.
Testing requirements for emergency lighting.
It is important that testing is.
Emergency lighting such as emergency escape lighting standby lighting fire safety signs and luminaires are provided for use when the supply to the normal lighting fails and are an essential requirement in the workplace.
Emergency lighting should be tested every month with an annual duration test to prove that the lighting can perform for the required duration typically three hours.
Code of practice for the emergency lighting of premises.
It is a duty holder s legal responsibility to ensure the health safety and welfare of their employees at work.
That way you know everyone can depend on it when they need to most.
All emergency lighting systems need testing monthly.
The uk fire safety legislation stipulates that the entire emergency light system must undergo a full test once a year.
With this option the code refers to nfpa 110 for the testing of emergency generators and related transfer switches and to nfpa 111 for testing stored electrical.
To do this you would simulate a mains power failure.
So for example if a luminaire is rated for a 3 hour duration then after 3 hours in an emergency situation the light should still be lit.
Maintaining your emergency lighting units ensures that all users have sufficient illumination in the event of an emergency to evacuate a building.
More details are set out on our dedicated emergency light testing page.
Tests should be recorded in a log book.
Emergency lighting usually takes effect automatically to provide sufficient levels of light for a minimum period of time in the event of sudden failure or loss of mains power supply.