So the next switch that we must press to be switch b s2.
Electronic combination lock circuit diagram.
This simple code lock circuit described here is of an electronic combination lock for daily use.
Key code lock switch circuit diagram.
Four of these xor gates compare the respective bits of two 4 bit binary numbers each number entered into the circuit via a set of switches.
Electronic circuit schematics note that all these links are external and we cannot provide support on the circuits or offer any guarantees to their accuracy.
One transistor electronic code lock system circuit design.
In this condition output o0 pin 2 of counter ic1 is high while all other outputs are low.
This electronic circuit is one of the simplest code lock circuit one can make easily in their home this circuit uses one transistor a relay and a few passive components in it the logic of this circuit is also very simple even this circuit is simple it works really fine and efficient for a simple cupboard or shelf lockers.
Electronic combination lock circuit circuit operation.
As you can see if we do not press the switch b it will not change any more of ic.
It will move the output from pin 3 to pin 2.
Electronic combination lock circuit.
This circuit illustrates the use of xor exclusive or gates as bit comparators.
This could be the circuit diagram of a easy electronic combination lock by using ic ls 7220 this circuit may be applied to activate a relay for controlling on off any device each time a preset combination of 4 digits are pressed the circuit may be operated from 5v to 12v.
Home circuits ua3730 combination lock modified.
Digital keypad combination lock this simple circuit is the electronic version of the combination lock.
The lock code can be set by connectiong the line wires to the pads a b c and d in the figure.
It responds only to the roght sequence of four digits that are keyed in remotely.
At power on capacitor c2 connected to pin 15 of ic1 charges to high level through 820 kilo ohm resistor holding the counter in the reset state.
In the stepdown transformer number of windings in the primary coil is less than the number of windings in the secondary coil.
It causes the positive voltage at the input of ic1 in next step.
Some circuits would be illegal to operate in most countries and others are dangerous to construct and should not be attempted by the inexperienced.
20 36 22 october 2013 this circuit based on the ua3730 ic with some modifiactions to produce a combination lock for a safe.
Next when ic1 has the input is a positive voltage.